Intumescent Fireproof Coating (2.0-2.5/2.0/1.5/1.0)
1K All
FIRE Specialty
Specialty Other All

Intumescent Fireproof Coating (2.0-2.5/2.0/1.5/1.0)

Overview

Water-based intumescent fireproof coating for structural steel. Formulated with acrylic emulsion, ammonium polyphosphate intumescent system, char-forming agents, blowing agents, and additives. On exposure to fire, the coating expands (intumesces) to form a thick, insulating char layer that protects the steel substrate.

Recommended Uses

  • Suitable for interior and exterior mineral substrates, concrete, mortar and prepared wall surfaces in general protective and decorative coating service.

Technical Data

Product Family Specialty
Coating Layer All
Component System 1K or ready-to-use system, confirm from current TDS
Recommended Use Snapshot Suitable for interior and exterior mineral substrates, concrete, mortar and prepared wall surfaces in general protective and decorative...
Surface Dry <=2h hard dry<=24h
Hard Dry <=24h
Dry Film Thickness 1.0happrox.1.0mm; 2.5happrox.3.5-5.0mm(depending on specific product)

Confirm current TDS/SDS, packaging, shelf life, export classification, and destination-market requirements before quotation or shipment.

Request Current TDS/SDS

Performance Data

Water Resistance >=24hno abnormality

Application Guide

Surface Preparation Steel or metal surfaces shall be dry, clean and free from oil, dust, mill scale and loose rust. Use the specified hand-tool, power-tool or blast-cleaning grade according to the coating system and service environment.
Application Environment Apply with application temperature 5-35 deg C; relative humidity <= 85%; substrate temperature at least 3 deg C above the dew point.
Application Method Apply by airless spray, air spray, spray, brush, roller. Recommended dry film thickness: 1.0happrox.1.0mm; 2.5happrox.3.5-5.0mm(depending on specific product). Use compatible thinner/cleaner such as clean water where permitted where specified. Mix, thin and recoat according to site conditions and the coating system requirements.

Export & Storage Notes

Safety Confirm substrate condition, compatibility, mixing ratio and application environment before large-area work. Protect from freezing, rain, contamination and direct exposure before the film is fully dry. Store sealed in a cool, dry and ventilated place and dispose of waste according to local regulations.

Product FAQ

Can I request the current TDS and SDS for Intumescent Fireproof Coating (2.0-2.5/2.0/1.5/1.0)?

Yes. Contact the Qilu Paints export team with the product name, destination country, substrate, coating system, and application environment to confirm current TDS/SDS, packaging, and export requirements.

How should Intumescent Fireproof Coating (2.0-2.5/2.0/1.5/1.0) be selected for an export project?

Confirm substrate preparation, exposure environment, target durability, compatible primer/intermediate/topcoat, destination-market documentation, and dangerous-goods classification before quotation or shipment.

What should be checked before applying Intumescent Fireproof Coating (2.0-2.5/2.0/1.5/1.0)?

Check surface cleanliness, surface profile, ambient temperature, substrate temperature, dew point, relative humidity, ventilation, mixing requirements, and recoat interval before application.

What should be checked before applying Intumescent Fireproof Coating (2.0-2.5/2.0/1.5/1.0)?

Confirm substrate cleanliness, surface profile, dew point, ambient temperature, humidity, and compatibility with the primer or topcoat in the coating system.

How should Intumescent Fireproof Coating (2.0-2.5/2.0/1.5/1.0) be mixed and applied?

Stir thoroughly before use. For multi-component products, mix base and curing agent according to the current TDS, observe induction time and pot life, and only thin with the recommended thinner.

How should unopened Intumescent Fireproof Coating (2.0-2.5/2.0/1.5/1.0) be stored?

Store in sealed original containers in a cool, dry, ventilated place away from heat, sparks, and direct sunlight. Confirm shelf life and packaging with the current TDS/SDS before shipment.

What safety precautions are required during application?

Use suitable PPE, provide ventilation, keep away from ignition sources, and follow the current SDS for handling, fire protection, first aid, and waste disposal.

Manufacturer & Product Data Source

This page is maintained by Shandong Qilu Paints Co., Ltd. for international buyers and is based on Qilu Paints legacy technical product records. Confirm current TDS/SDS, export classification, packaging, shelf life, color, and destination-market requirements with the sales and technical team before quotation, specification, or shipment.

Manufacturer Shandong Qilu Paints Co., Ltd.
Export contact sales@qilupaints.com
Technical review Current TDS/SDS required

Disclaimer

The listed data are typical reference values. Actual consumption, drying time, recoating interval and final performance depend on substrate condition, film thickness, temperature, humidity, ventilation, application method and coating system. For certification, special exposure, fire rating, potable-water contact, food contact or VOC-limit requirements, use the applicable test report, certificate or confirmed technical agreement.