High Chlorinated Polyethylene (HCPE) Topcoat
1K Top
QL-CR-T-004 Chlorinated

High Chlorinated Polyethylene (HCPE) Topcoat

Description

Composition: high-chlorinated polyethylene resin, modified resin, plasticizer, weather-resistant pigment, additives, solvents, etc. it can be widely used for surface anti-corrosion of various industrial equipment and facilities in industries such as metallurgy, petroleum, chemical engineering, electricity, and machinery

High Chlorinated Polyethylene (HCPE) Topcoat is composed of high-chlorinated polyethylene resin, modified resin, plasticizer, weather-resistant pigment, additives, solvents, etc. It can be widely used for surface anti-corrosion of various industrial equipment and facilities in industries such as metallurgy, petroleum, chemical engineering, electricity, and machinery.

Best For

  • chemical atmospheres
  • pool and wastewater environments
  • aggressive industrial service

Buyer Benefits

  • chemical resistance profile
  • single-pack maintenance option
  • useful for wet or aggressive environments

Key Features

  • Excellent weather aging resistance.
  • Good resistance to chemical industrial atmosphere corrosion.
  • Quick drying.
  • Strong adhesion.
  • Can be applied at low temperatures.
  • Good high - and low - temperature resistance.
  • Easy to use.
  • Good flame retardancy and mildew resistance.
  • The coating has strong adhesion to the surfaces of various steel structures, concrete facilities, etc.

Typical Coating System

Typical chlorinated system: compatible primer plus chlorinated rubber intermediate or topcoat selected according to chemical exposure.

Technical Specifications

Product Family Chlorinated
Coating Layer Top
Component System 1K or ready-to-use system, confirm from current TDS
Recommended Use Snapshot chemical atmospheres, pool and wastewater environments
Typical System Typical chlorinated system: compatible primer plus chlorinated rubber intermediate or topcoat selected according to chemical exposure.

Confirm current TDS/SDS, packaging, shelf life, and destination-market requirements before quotation or shipment.

Request Current TDS/SDS

Application Guide

Application Method 1. Surface Preparation: The surface to be painted must be thoroughly cleaned before construction to ensure that there is no rust, oil, water stains, dust, etc., on the surface. 2. Application Conditions: The substrate temperature must be at least 3°C higher than the dew point temperature. Construction temperature should be between 5°C and 35°C. The relative humidity should not exceed 85%. 3. Painting method (see the construction plan of high-chlorinated polyethylene paint for details): Air spraying Diluent: High-chlorinated polyethylene thinner Dilution ratio: 35-40% Nozzle diameter: 2.0-3.0mm Spraying pressure: 0.3-0.6Mpa (about 3-6Kg/cm²) Cleaner: High-chlorinated polyethylene thinner 4. Recommended number of painting coats: Two coats, with a dry film thickness of 60-80um. 5. Painting interval: For substrate temperatures: The minimum interval is 24 hours at 5°C, 8 hours at 20°C, and 6 hours at 30°C; the maximum interval is 7 days. Compatible paints for the previous coat: 6. High-chlorinated polyethylene intermediate paint and high-chlorinated polyethylene iron red primer.

Product FAQ

Can I request the current TDS and SDS for High Chlorinated Polyethylene (HCPE) Topcoat?

Yes. Contact the Qilu Paints export team with the product name, destination country, and application environment to confirm current TDS/SDS, packaging, and export requirements.

How should High Chlorinated Polyethylene (HCPE) Topcoat be selected for a coating system?

Confirm substrate, exposure environment, required durability, compatible primer or topcoat, and destination-market documentation before quotation or shipment.

What should be checked before applying High Chlorinated Polyethylene (HCPE) Topcoat?

Check surface cleanliness, surface profile, ambient temperature, substrate temperature, dew point, and relative humidity before application. Stir thoroughly before use.

How should High Chlorinated Polyethylene (HCPE) Topcoat be stored and handled?

Store sealed containers in a cool, dry, ventilated area away from heat, sparks, and direct sunlight. Follow the current SDS for PPE, ventilation, fire prevention, and waste disposal.

What should be checked before applying High Chlorinated Polyethylene (HCPE) Topcoat?

Confirm substrate cleanliness, surface profile, dew point, ambient temperature, humidity, and compatibility with the primer or topcoat in the coating system.

How should High Chlorinated Polyethylene (HCPE) Topcoat be mixed and applied?

Stir thoroughly before use. For multi-component products, mix base and curing agent according to the current TDS, observe induction time and pot life, and only thin with the recommended thinner.

How should unopened High Chlorinated Polyethylene (HCPE) Topcoat be stored?

Store in sealed original containers in a cool, dry, ventilated place away from heat, sparks, and direct sunlight. Confirm shelf life and packaging with the current TDS/SDS before shipment.

What safety precautions are required during application?

Use suitable PPE, provide ventilation, keep away from ignition sources, and follow the current SDS for handling, fire protection, first aid, and waste disposal.